Solar Solution Engineering
Photovoltaic system, energy modeling and definition of electrical architecture for plant.
Design, construction, CFE grid interconnection, commissioning and monitoring of photovoltaic projects starting at 500 kWp, under a single contract.
We design industrial photovoltaic systems for the sectors with the highest energy consumption and critical operational continuity in Mexico and Latin America.
PV sizing that does not consider module degradation, partial shading, and actual switchgear temperature produces generation projections 8-15% higher than operation. This difference compromises the return committed to the investment committee.
The MV interconnection ruling procedures under NOM-001-SEDE and the CFE contract can take from 3 to 9 months if the link engineering is not ready from the beginning. A solar project paralyzed in ruling continues to generate financial costs without producing a kWh.
Variable generation can introduce harmonics and micro-outages into sensitive production lines—paint, pharmaceutical, electronics—if proper backup or filtering is not integrated. The generator-grid transition without controlled bypass is another frequent risk point.
We integrate end-to-end industrial solar solutions to reduce energy costs, improve sustainability and ensure operational performance.
Photovoltaic system, energy modeling and definition of electrical architecture for plant.
Integration of modules, inverters and electrical panels with coordination of on-site assembly.
Performance testing, protection verification, connection and documented operational delivery.
From energy evaluation to commissioning, with technical traceability and phased execution.
Implementations of solar generation and energy integration for industry with efficiency and resilience objectives.
Integration of electrical infrastructure to improve energy efficiency and reliability.
400 kV power cable systems for hydroelectric turbines, with execution in critical environment.
Increase in capacity with operational continuity in the plant.
Includes engineering, technical supply, assembly, testing, interconnection and commissioning of the solar system.
Yes. We plan intervention windows and execution phases to minimize operational continuity impacts.
Yes. We prepare the network impact study, complete technical documentation and accompany the opinion process until the contract of interconnection is signed in MV or LV.
We select according to power, redundancy and required SCADA protocol: SMA, Sungrow, ABB, Fronius. We provide string monitoring with real-time dashboard and monthly report.
Yes. We design hybrid solar+BESS systems with dispatch algorithms, and on-island operation for plants with maximum demand restrictions.
Real-time dashboard with performance vs PVsyst, alerts per string, module and inverter temperature, and monthly report of energy generated with system availability.
Engineering and management of CFE opinion: 8-14 weeks. Equipment supply: 6-12 weeks. Installation and commissioning: 4-8 weeks depending on power and access to the site.
Photovoltaic modules with a 12-year product warranty and a 25-year linear performance warranty (>80%). Inverters with a 5-10 year factory warranty depending on the manufacturer, extendable with a maintenance contract.
Share your requirement in the contact form and we define scope, times and technical proposal.
Filter by category and quickly find the right service for your project.
We did not find services with these filters. Try another category or keyword.
A solar park has four different cable fronts — each with its own physics, regulation and fault mode. Confused a string cable with a trunk cable or an AC with an interconnection MV is the most frequent cause of premature rating and CFE decision problems. We supply the four fronts integrated into EPC reach.
PV1-F KEI cable, Class 5 tinned copper conductor, halogen-free cross-linked polyolefin insulation. Nominal voltage 0.6/1 kV AC, up to 2000 V DC. Typical sections 4–16 mm². Useful life 30 years with resistance to UV, ozone and thermal cycles.
PV1-F in larger sections (25–50 mm² or more depending on the power of the central inverter and voltage drop limit). For underground runs, specify additional cover or pipe protection — the standard PV1-F is not for direct burial.
LV/MV power cable on the AC side of the inverter. Selection by nominal current of the inverter, distance to the transformer and voltage drop limit. Construction with reinforcement for typical buried sections in utility scale parks.
MV XLPE power cable for the section from the park substation to the interconnection point with CFE. Typical voltages 13.8–34.5 kV. Specification under LAPEM so that the CENACE/CFE interconnection ruling is not hindered by cable issues.
| Application | Typical section | Allowable current* |
|---|---|---|
| Standard String | 4–6 mm² | 42–52 A |
| Long String / High Current | 10–16 mm² | 76–95 A |
| Troncal DC to investor | 25–50 mm² | 125–185 A |
| Long trunks / Green scale | 70–120 mm² | 239–335 A |
* Reference values at 40 °C in air according to KEI PV1-F technical sheet. Final selection adjusts for actual site temperature, clustering, and project voltage drop limit. What is ampity?
We size gauges for string and trunk, specify the AC and MV cable under LAPEM, manage the interconnection opinion with CENACE/CFE and deliver the cable coordinated with the module installation schedule. A single technical responsibility from the DC to the interconnection point.
We analyze demand, scope and ROI to send you a technical proposal. We will contact you in less than 24 business hours; The proposal time depends on the scope. Projects from $1,000,000 MXN.
Autonomous photovoltaics for offshore installations: arrangement, load control, investment and backup in batteries, where there is no grid to connect to.
AKAL-H Platform — Cotemar / Pemex
Campeche (offshore)
Installation and commissioning of a photovoltaic system on a platform.
AKAL · Zonda — Campeche Maritime Services / Pemex
Campeche (offshore)
Manufacture, supply and pre-operational electrical testing of a photovoltaic system composed of photovoltaic array, charge control unit, power inverter, battery bank and distribution board.
Cotemar
Ciudad del Carmen, Campeche
Supply of solar panels for gas and fire system.