Specification and selection
Voltage, nominal current, interrupting capacity, compartmentalization and protection scheme, from short circuit study and installation coordination.
Supply, refurbishment and commissioning of distribution switchgear and switchboards for 4.16 at 34.5 kV for industry and power generation. We refurbish the installed section when full replacement is not the right solution.
We do not sell a cabinet: we deliver the section working and tested, with the documentation that the maintenance area will need in ten years. Each front is contracted loosely or within a full EPC scope.
Voltage, nominal current, interrupting capacity, compartmentalization and protection scheme, from short circuit study and installation coordination.
switchgear, switchgear, instrument transformers and accessories, with tracking of the factory schedule to site.
Leveling, anchoring, bar coupling, power and control connection, and grounding.
If the switchgear is healthy and the switch or a section failed, that part is replaced instead of the entire board. We did it on two CFE Transmission metal-clad boards.
Insulation and contact resistance, operating times, interlocks and point-to-point verification of the control before energizing.
For cogeneration and generation: synchronization logic, mechanical and electrical interlocks, and interconnection protection.
A medium voltage switchgear is the assembly of aparamenta — switch, seccionators, fuses, protections and measurement — housed in a metal envelope to control and protect circuits of more than 1 kV and up to 36 kV (IEC classification). They are chosen by two axes.
Air at atmospheric pressure; normally vacuum switch.
Area in electric room
The most common in industry. Simple and with accessible components, in exchange for more surface area.
Gas bars or switch; the rest in air.
Area in electric room
Midpoint. It takes up less space than an AIS without reaching the cost of a complete GIS.
Active parts in sealed tank with SF6 or another gas.
Area in electric room
Platforms, coast, mines and small rooms. Requires monitoring gas pressure; An internal fault is repaired at the factory.
Relative comparison between the three options, not measured by a particular manufacturer.
What is specified in each section depends on its function: connection, link, feeder, transformer protection or measurement.
They receive energy from the CFE network and distribute it within the plant.
They power transformers, CCMs and medium voltage motors.
Own generation synchronization and interconnection switchgear.
Three from VMS Energy's project catalogue. Each card says only what is in it.
CFE Transmission
Jalisco
Supply and installation of spare parts for the rehabilitation of the section with switch ALS 5315 Board Link Metal-clad..
CFE Transmission
Jalisco
Supply and installation of spare parts for the rehabilitation of the section with switch ALS 56-235 Board Link Metal-clad..
Ingenio Adolfo López Mateos
Oaxaca
Engineering, supply and commissioning of the Synchronization switchgear cogeneration system, with equipments MSCL II and DECS 250 on board.
Two references, not a long list: the one that governs the switchgear and the one that governs the installation in Mexico.
High voltage switchgear. General and particular requirements for MV/HV switches, disconnectors and shielded switchgear.
Electrical installations. Official Mexican standard that governs the installation, distances, grounding and protection of the assembly once assembled.
Single-line diagram, available short circuit study and site conditions.
Data sheet of the switchgear and its switchgear, with coordinated protections.
Factory schedule, tracking and logistics to site.
Anchoring, coupling, power and control connections, landing.
Site acceptance protocol, with documented results.
Assisted energization and delivery of the technical file.
It is the document that decides whether the switchgear you have installed is still adequate, and the one that avoids quoting based on assumptions. If you don't have it, we make it.