VMS Energy · Electrical equipment · Medium voltage

Medium-voltage switchgear

Supply, refurbishment and commissioning of distribution switchgear and switchboards for 4.16 at 34.5 kV for industry and power generation. We refurbish the installed section when full replacement is not the right solution.

Metal-clad and metal-enclosed IEC 62271 CFE Transmission · mills · mining
Scope

What do we do with a medium voltage switchgear

We do not sell a cabinet: we deliver the section working and tested, with the documentation that the maintenance area will need in ten years. Each front is contracted loosely or within a full EPC scope.

Specification and selection

Voltage, nominal current, interrupting capacity, compartmentalization and protection scheme, from short circuit study and installation coordination.

SUPPLY

switchgear, switchgear, instrument transformers and accessories, with tracking of the factory schedule to site.

Assembly and connection

Leveling, anchoring, bar coupling, power and control connection, and grounding.

Rehabilitation of sections

If the switchgear is healthy and the switch or a section failed, that part is replaced instead of the entire board. We did it on two CFE Transmission metal-clad boards.

Testing and commissioning

Insulation and contact resistance, operating times, interlocks and point-to-point verification of the control before energizing.

Synchronization switchgear

For cogeneration and generation: synchronization logic, mechanical and electrical interlocks, and interconnection protection.

How to decide

Types of medium voltage switchgear

A medium voltage switchgear is the assembly of aparamenta — switch, seccionators, fuses, protections and measurement — housed in a metal envelope to control and protect circuits of more than 1 kV and up to 36 kV (IEC classification). They are chosen by two axes.

1 Degree of compartmentalization: how much can be maneuvered with the panel energized

Side cut of a metal-clad switchgear with four compartments: control, removable switch, bars and cables LV control Relays Switch removable Bars Cables TC Front Later
Metal-clad. Grounded metal compartments for bars, switch, cables and control; removable switch with shutters . To maneuver and perform maintenance without taking the rest of the board out of service.
Side cut of a metal-enclosed switchgear: separate control and a single medium voltage space for switch, bars and cables LV control Relays Bars Fixed TC One MV space Front Later
Metal-enclosed. Metallic enclosure without complete separation. Lower cost and equal protection against direct contact, with less hot work capacity.
Isolating switchgear: disconnector with fuses in the branch, without power switch bars/ring Disconnector Fuse a Transformer o Derivation
Sectioning and distribution. Switching and sectioning in rings and branches, without the interruption capacity of a power switch.

2 Insulating medium: air, gas or hybrid

Air-insulated (AIS)

Air at atmospheric pressure; normally vacuum switch.

Area in electric room

  • Initial cost
  • Dust, moisture and salinity tolerance
  • Access for on-site maintenance

The most common in industry. Simple and with accessible components, in exchange for more surface area.

Hybrid or compact

Gas bars or switch; the rest in air.

Area in electric room

  • Initial cost
  • Dust, moisture and salinity tolerance
  • Access for on-site maintenance

Midpoint. It takes up less space than an AIS without reaching the cost of a complete GIS.

Gas insulated (GIS)

Active parts in sealed tank with SF6 or another gas.

Area in electric room

  • Initial cost
  • Dust, moisture and salinity tolerance
  • Access for on-site maintenance

Platforms, coast, mines and small rooms. Requires monitoring gas pressure; An internal fault is repaired at the factory.

Relative comparison between the three options, not measured by a particular manufacturer.

What's inside

Components and applications of a medium voltage switchgear

What is specified in each section depends on its function: connection, link, feeder, transformer protection or measurement.

The switchgear of a feeder section

Single-line diagram of a feeder section with numbered switchgear MV bars interlocking to transformer, MCC or MV engine Relay 50/51 · 87 · 27/59 shot 1234556
Simplified unifilar. Numbers correspond to the list.
  1. 1
    Power switch. Opens and closes under load and interrupts overcurrents and short circuits. Vacuum or SF6, fixed or removable.
  2. 2
    Disconnector and ground blade. They isolate a part of the system and ground it to work safely. They do not interrupt fault current.
  3. 3
    Limiting fuses. They protect against overcurrent, especially in branches to transformers and in sectional switchgear.
  4. 4
    Protection relays. They measure current and voltage and order the trip: phase and ground overcurrent, differential, under and over voltage. Its adjustment comes from the coordination study.
  5. 5
    Instrument transformers (TC and TP). They reduce current and voltage to values ​​that relays and meters read.
  6. 6
    Bars, interlocks and control. The bars distribute the energy between sections; Interlocks prevent maneuvers in incorrect sequence.

Where they are installed

Connection and main substation

They receive energy from the CFE network and distribute it within the plant.

13.8 kV23 kV34.5 kV

Industrial distribution

They power transformers, CCMs and medium voltage motors.

MiningOil & GasFood and drinksWits

Generation and interconnection

Own generation synchronization and interconnection switchgear.

CogenerationEmergencySolar · windBESS
References

Works executed on switchgear and boards of medium voltage

Three from VMS Energy's project catalogue. Each card says only what is in it.

Rehabilitation · metal-clad

CFE Transmission

Jalisco

Supply and installation of spare parts for the rehabilitation of the section with switch ALS 5315 Board Link Metal-clad..

Rehabilitation · metal-clad

CFE Transmission

Jalisco

Supply and installation of spare parts for the rehabilitation of the section with switch ALS 56-235 Board Link Metal-clad..

Synchronization switchgear · cogeneration

Ingenio Adolfo López Mateos

Oaxaca

Engineering, supply and commissioning of the Synchronization switchgear cogeneration system, with equipments MSCL II and DECS 250 on board.

Regulatory framework

Under what is specified and tested

Two references, not a long list: the one that governs the switchgear and the one that governs the installation in Mexico.

IEC 62271

High voltage switchgear. General and particular requirements for MV/HV switches, disconnectors and shielded switchgear.

NOM-001-HEADQUARTERS

Electrical installations. Official Mexican standard that governs the installation, distances, grounding and protection of the assembly once assembled.

How we work

From request to energized switchgear

  1. Step 1

    Uprising

    Single-line diagram, available short circuit study and site conditions.

  2. Step 2

    Specification

    Data sheet of the switchgear and its switchgear, with coordinated protections.

  3. Step 3

    SUPPLY

    Factory schedule, tracking and logistics to site.

  4. Step 4

    Assembly

    Anchoring, coupling, power and control connections, landing.

  5. Step 5

    Tests

    Site acceptance protocol, with documented results.

  6. Step 6

    Commissioning

    Assisted energization and delivery of the technical file.

Frequently asked questions

What they ask us before quoting

What is a medium-voltage switchgear?
It is a metal enclosure that houses the switchgear to operate, protect and measure a circuit of more than 1 kV and up to 36 kV: switches, disconnectors, fuses, protection relays and instrument transformers. Several switchgear coupled by bars form a medium voltage distribution board.
What is the difference between an isolated air switchgear (AIS) and a gas isolated switchgear (GIS)?
AIS uses air as an insulator: it is cheaper and more accessible for maintenance, but it takes up more space. The GIS encloses the active parts in gas (typically SF6): it is compact and immune to dust, humidity and salinity, but costs more and requires monitoring the gas pressure. GIS is chosen when space or environment requires it; in the rest of the cases, AIS.
Should the switchgear be rehabilitated or the board replaced?
It depends on where the wear is. If the envelope, the bars and the compartments are healthy and what failed is the switch or a specific section, replacing that part is faster and avoids re-engineering of civil works and pipelines. If the switchgear no longer has spare parts or the short circuit level of the installation has grown above the capacity of the panel, replacing is the answer. The short circuit study is what decides, not the age of the equipment.
What is needed to quote a switchgear?
At a minimum: nominal voltage, nominal bus current, short-circuit current available at that point, number and function of the sections, and whether the switchgear is installed indoors or outdoors. With the one-line diagram and the short circuit study, the quote comes out without assumptions.
Is the difference between metal-clad and metal-en-ln-ln is only price?
No. Metal-clad separates the bars, switch, cables and control into grounded metal compartments, and has a removable switch with shutters. This is what allows one section to be maneuvered and maintained with the rest of the deck in service. Metal-enclosed protects against direct contact but without that complete separation. The decision is made for operational continuity, not cost.
Do they put into service or just supply?
Both things, and also separately. VMS Energy executes the complete scope—specification, supply, assembly, testing and energization—or enters only the part that is needed, which is usual in rehabilitations on panels that are already installed.

Do you have the short-circuit studio for that substation?

It is the document that decides whether the switchgear you have installed is still adequate, and the one that avoids quoting based on assumptions. If you don't have it, we make it.