LV and MV industrial electric motors
Supply, installation, alignment and repair of low- and medium-voltage industrial engines. IE3/IE4 high-efficiency solutions, ATEX/NEC 500 rated area engines and field or workshop rewinding — with selection engineering included.
When the engine fails, the plant stops
In a typical plant, 70–80% of the electrical energy is consumed by the motors. Going from IE2 to IE3 reduces consumption by 3–6% per motor. With fleets of dozens of units, the return on investment is usually less than 18 months.
Oversize, mis-chosen service factor, insufficient insulation class or standard engine in classified area are frequent errors. A poorly selected engine fails ahead of schedule and cancels the manufacturer's warranty.
Misalignment between motor and load causes 50% of premature bearing and mechanical seal failures. VMS Energy includes laser alignment and functional testing on every new installation — not as an extra, but as standard.
Supply, installation and service of engines
LV induction motors — 0.75 to 500 HP
Selection, supply and installation of low voltage three-phase induction motors (220–690 V) in NEMA or IEC housings. Applications in pumps, fans, compressors, conveyors and mixers. Brands: WEG W22, ABB M2BAX, Marathon Severe Duty.
IE3/IE4 high efficiency motors
Premium and Super Premium motors to reduce energy consumption and comply with international NOM and MEPS regulations. Comparative life cycle cost (LCC) assessment IE2 vs IE3 vs IE4 included. Typical savings: 3–8% of electric bill per motor replaced.
MV medium voltage motors — 2.3 to 13.8 kV
Supply and installation of MV engines for high-powered applications: gas compressors, transfer pumps, industrial mills and extrusoras. Powers from 200 HP to 10 000+ HP. Brands: WEG, Innomotics (Siemens), ABB. Including protection coordination with multi-function relief.
Motors for ATEX / NEC 500 classified area
Explosion-proof (Ex d), increased safety (Ex e) and non-scintillating (Ex n) motors for Oil & Gas facilities, chemical and grain processing plants. Temperature groups T3–T4. ATEX, IECEx and NEC 500 Class I Div 1 and Div 2 certifications. Brands: WEG Ex, Marathon DRIP-PROOF / TENV.
Installation, alignment and commissioning
Mechanical and electrical installation, precision laser alignment, phase current balance, insulation verification (megger), load functional test and thermal protection adjustment. Delivery with start-up protocol and registration of base parameters.
Rewinding and repair of industrial motors
Electrical and mechanical diagnosis, rewinding of LV/MV stators with high conductivity copper wire, replacement of bearings, VAC varnish treatment and hi-pot insulation tests. Repair with 12 month warranty. Own and third-party brands.
Classification of motors by application
| Type of engine | Power range | Voltage | Efficiency | Typical applications | VMS brands |
|---|---|---|---|---|---|
| Standard LV induction motor | 0.75–500 HP | 220–690V | IE2/IE3 | Pumps, fans, conveyors | WEG W22 · ABB M2BAX · Marathon |
| IE3/IE4 high efficiency motor | 1–500 HP | 220–690V | IE3/IE4 | 24/7 applications with high average load | WEG W22 IE4 · ABB IE4 |
| Medium voltage MV motor | 200–10,000+ HP | 2.3–13.8 kV | IE2/IE3 | Compressors, mills, MV pumps | WEG · Innomotions · ABB |
| Ex d classified zone engine | 0.75–400 HP | 220–690V | IE2/IE3 | Oil & Gas, platforms, chemical plants | WEG Ex · Marathon Cl.I Div.1 |
| Motor for VFD (inverter duty) | 1–500 HP | 220–690V | IE3 | Pumps and fans with frequency converter | WEG W22 VFD · ABB M2BAX invert |
| Severe Duty Engine | 1–500 HP | 220–690V | IE3 | Mining, agribusiness, aggressive environments | Marathon Severe Duty · WEG W60 |
Brands we work with
Brazilian world leader. Complete range LV/MV, IE4 SynRM, Ex d/e, motors for VFD. Extensive spare parts support in Mexico.
Swiss-Finnish manufacturer of global reference. M2BAX, NEMA, IEC motors and IE4/IE5 synchronous reluctance motors. High power density.
North American NEMA standard manufacturer. Severe Duty motors with robust casing for aggressive industrial environments and continuous duty applications.
German manufacturer specializing in medium and high voltage motors for process applications. Leader in high power engines for Mining, Oil & Gas and generation.
Sectors we serve
Pumping, compression, Ex zone — Class I Div 1/2
Mills, belts, mine fans — Severe Duty
Irrigation pumps, silos, processors
Compressors, mixers, extruders, presses
Pumping drinking water, wastewater, HVAC
Generation auxiliaries, coolers, tower fans
How we manage your engine project
1. Selection engineering
Application survey: resistive torque curve, load cycle, installation environment, area classification, applicable standard (NEMA/IEC) and physical space restrictions. We provide calculation report and recommended engine sheet before quoting.
2. Supply and logistics
Management of purchase, import and delivery on site of the selected engine. Physical verification upon receipt: data plate, bearings, winding insulation and casing. For critical equipment we coordinate FAT at the manufacturer's plant if required.
3. Installation and alignment
Mechanical assembly, precision laser alignment (parallel and angular ≤ 0.05 mm), laying and connection of power and control wiring, adjustment of thermal protections and supervised start-up. Alignment protocol delivered as a quality document.
4. Start-up and monitoring
Full load functional test: measurement of phase currents, case temperature, base vibration (ISO 10816) and power factor. Recording of parameters as a baseline for future predictive maintenance. Post-delivery support included.
Motors and generators serviced
Specialized maintenance of industrial engines and generators on offshore vessels, marine platforms and land plants in the Oil & Gas sector.
Cotemar — Olimpo Ship
Veracruz
Specialized maintenance on 4 Leroy Somer electric generators 590 kW, 440 V, 1,800 RPM and 2 Hyundai Bow Thruster engines 1,050 kW, 690 VAC.
Cotemar — Atlas Vessel
Veracruz
Maintenance of 4 Leroy Somer 590 kW generators and 2 Hyundai 1,050 kW Bow Thruster engines. Performance tests and adjustment of protections on vessels in operation.
Cotemar — Saturno Ship
Veracruz
Service to 2 self-excited synchronous generators (brushless) Stamford 1 280 kW, 2 000 A, 440 V. Diagnosis of devanes, cleaning and isolation tests.
Cotemar — Hercules Vessel
Veracruz
Major maintenance on Bow Thruster Hyundai engine 1,050 kW, 690 VAC, 883 RPM. Review of windings, bearings and mechanical alignment.
Cantarell Nitrogen Plant — LINDE
Jalisco
Maintenance of Hyundai 2 560 HP squirrel cage engine and 600 HP engine in nitrogen generation plant for Cantarell operations.
Chinese ship
Veracruz
Maintenance, installation and commissioning of Woodward PGD speed governors on boats.
Frequently asked questions
What motor power ranges do you supply?
Low-voltage induction motors (220–690 V) from 0.75 to 500 HP and medium-voltage motors from 2.3 to 13.8 kV, rated from 200 HP to more than 10 000 HP, from brands such as WEG, ABB, Marathon and Innomotics (Siemens).
How much can be saved by upgrading to an IE3 or IE4 high-efficiency motor?
Upgrading from IE2 to IE3 reduces electricity consumption by 3 to 6 % per motor; typical replacement savings amount to 3 to 8 % of that motor's electricity bill. For fleets of dozens of units, payback is usually under 18 months. We include an IE2 vs. IE3 vs. IE4 life-cycle cost assessment.
Do you supply motors for hazardous locations?
Yes: explosion-proof motors (Ex d), increased-safety motors (Ex e) and non-sparking motors (Ex n), with ATEX, IECEx and NEC 500 Class I Div 1 and Div 2 certifications, for Oil & Gas, chemical plants and grain processing facilities.
Does installation include alignment?
Yes. Every new installation includes laser alignment, insulation verification, current balancing, functional testing under load and thermal protection adjustment, with a commissioning protocol. Misalignment causes nearly half of premature bearing and seal failures.
Do you repair and rewind motors?
Yes. Electrical and mechanical diagnostics, LV and MV stator rewinding, bearing replacement, VAC varnish and hi-pot insulation testing, either on-site or in the workshop, with a 12-month warranty.
Do you need a new, more efficient engine or for classified area?
Our engineering team selects the right motor for you – power, efficiency, protection and housing – before quoting. No purchase commitments in the technical consultation.