Free tool · VMS Energy

BESS Savings Calculator
Peak-Shaving GDMTH

Estimate the sizing and monthly savings of your energy storage system to reduce the demand charge in the medium voltage hourly rate.

Applies to GDMTH · GDMTO · GDBT · PDBT rates

CFE & Demand rate

Select the rate that appears on your CFE receipt and capture the demand data.

Peak recorded in CFE receipt

Goal after peak-shaving with BESS

Capture the demand recorded in each period of your CFE receipt (charge table). The BESS is sized against the peak of Tip.

PeriodCurrent demand (kW)Target demand (kW)Hours/dayDays/month
Tip
Intermediate
Base

Peak Profile

Defines how many hours per day demand peaks occur and confirms the tariff charge.

Typical: 2–6 hours in heavy duty

Pre-filled according to selected rate. Adjust with the value of your last CFE receipt.

PeriodCharge $/kW·monthTypical schedule
Tip 18:00–22:00 M-S
Intermediate 06:00–18:00 / 22:00–24:00
Base 00:00–06:00

i Schedules vary by CFE region. Check the dorso of your receipt or the tariff table in cfe.mx.

Average energy rate (for calculation of Solar Bonus)

Period$/kWhUse BESS
Tip BESS discharge → max. savings
Intermediate Solar generates here (self-consumption value)
Base BESS recharge → lower cost

Arbitration: the Punta-Base differential (typical ) is added as additional savings to the "Corque-s" [2.40].

Solar Integration (optional)

If you already have solar panels, BESS can raise your self-consumption from 60% to 85% approximately.

~4 h/day × kWp as fast estimate

Tax benefit

Machinery and equipment to generate energy with renewable sources can be deducted 100% (art. 34-XIII LISR). For storage there is no published criterion from the authority: the treatment depends on each project, for example, on whether the BESS is charged with solar energy. This is reference information, not tax advice: the profit depends on the situation of each company and the legislation in force. Confirm it with your accountant before considering it in the investment decision.

Your results will appear here

Complete the 3 steps of the form
and press Calculate

Results for your installation

additional MXN/month

by raising solar self-consumption from 60% to 85% with BESS.

BESS required
— kW
— kWh
Monthly savings
— MLB

Demand profile: before vs. after

i Indicative estimate based on published CFE rates and standard market parameters. The actual value depends on your load profile, tariff trading, and installation conditions. Request a detailed technical-financial study from VMS Energy.

How does the "Cum-s" work with BSS?

In the GDMTH rate, CFE invoices the demand charge on the maximum kW registered in a 15-minute interval during the month. The BESS is discharged right at those peaks to reduce that record.

Peak detection

The BESS BMS monitors demand in real time and identifies the onset of a peak event.

BESS download

The bidirectional inverter injects power from the batteries to trim the peak before CFE records it.

Recharge in valley

During hours of low demand (early morning or solar) the batteries are recharged for the next cycle.

Reduced bill

CFE registers a lower maximum demand and the monthly charge falls immediately and sustainably.

You want a detailed study?

VMS EnergySheer and quote your BESS with real load profile

See solutions BESS →

Frequently asked questions

What information do I need to use the calculator?

Your CFE electricity bill: contracted tariff, maximum demand recorded in each billing period, demand charge and energy cost. If you have solar panels, also provide installed capacity and daily generation.

What is BESS peak shaving?

It means using batteries to cover demand peaks and lower the maximum demand recorded by CFE under the GDMTH tariff. The system is sized against peak demand.

How accurate is the result?

This is an indicative estimate based on published CFE tariffs and standard market parameters. Actual savings depend on your load profile and installation conditions; request a techno-economic study from VMS Energy before making a decision.

Is a BESS tax-deductible?

Equipment used to generate power from renewable sources may qualify for a 100 % tax deduction (Article 34-XIII of Mexico's Income Tax Law, LISR), but there is no published tax-authority criterion for storage and treatment depends on each project. This is reference information, not tax advice: confirm it with your accountant.