Frequency Variations
Energy Savings and Process Control
Multi-brand supply, installation, commissioning and maintenance of industrial VFDs for the industry in Mexico. Regulations applied according to the requirements of the project.
Law of affinity — why VFDs save so much
A centrifugal pump controlled by variator consumes drastically less than with butterfly valve regulation, where the engine always rotates at nominal speed.
Topologies of variable frequency drives that we supply and install
Selection depends on voltage level, power, EMC requirements, regenerative capacity and process communication protocol.
VFD 2 levels — VSI (Voltage Source Inverter)
More widespread topology. Rect. diodes + DC bus + IGBT bridge. Range 0.37–2 500 kW, voltages 220–690 V AC. THDi without filter 35–45%; with 20–25% line reactor; with LCL filter <5%. Suitable for most pumps, fans, compressors and belts.
VFD 3 levels — NPC (Neutral Point Clamped)
For medium voltage motors 2.3–6.6 kV and powers from 315 kW to several MW. The multilevel design reduces dv/dt over the motor winding and improves the waveform (THDv <5% without extra filter). Requires input isolation transformer.
AFE — Active Front End (active rectification)
Replaces the diode bridge with an active IGBT bridge. Key advantages: THDi <3% (IEEE 519), unity power factor (0.99) and energy recovery to the grid in regenerative mode. Ideal for cranes, elevators, presses, drilling machines and applications with frequent or continuous braking.
Multi-drive / Common DC Bus
Several inverters share a common DC bus powered by a centralized rectifier or shared AFE. The braking energy of one axle is reused on another motor axis. It is borderlined the number of rectifiers, improves overall THD and is optimal in machines with multiple coordinated axes (production lines, winders, looms).
Harmonic management according to IEC 61000-3-12 / IEEE 519
The THDi level determines whether a line reactor, passive LCL filter, or an active front-end is required. VMS Energy designs the solution according to the network capacity and the requirements of the applicable standard.
Standard VFD without filter
Rect. 6-pulse diode without mitigation. Exceeds IEEE 519 limits (<5% in industrial PCC)
With 3%Uk line reactor
Economic solution.Current current peaks and improves displacement power factor
With passive LCL filter
Complies with IEC 61000-3-12 and IEEE 519 in industrial environments. Recommended when THD affects other equipment
VFD with AFE (active rectif)
Best possible performance. Complies even on sensitive networks (hospitals, data centers, platforms)
Key parameters for specifying a drive
A complete data sheet allows you to select the right family and size, avoiding oversize or premature failure due to thermal overload.
| Parameter | Detail / Typical ranges | Impact on selection |
|---|---|---|
| Motor power (kW / HP) | 0.37 kW – several MW | Determines the product family and chassis size |
| Network voltage | 220 V / 380–480 V / 525–690 V / MV 2.3–6.6 kV | Define LV vs. MV; may require xfmr isolation |
| Load type | Variable torque (pumps/fans) vs. constant torque (compressors, belts, extruders) | Variable torque allows derating; constant torque requires nominal gauge |
| Load Cycle Profile | % permissible overload (110% / 150% for 60 s) | Determine if the next size is required |
| Topology required | VSI 2L, NPC 3L, AFE, Multi-D | Defines THD level, regeneration and cost |
| Installation altitude | AMSL (m n.m.) | Derating −1%/100 m over 1 000 m |
| Ambient temperature | Max. 40°C standard; derating −1.5%/°C over 40°C | May require larger chassis or additional forced ventilation |
| Communication protocol | Modbus RTU/TCP, Profibus DP, EtherNet/IP, PROFINET, DeviceNet | Defines compatibility with existing PLC/SCADA |
| Degree of protection | IP20 (electrical room) / IP54–IP66 (field, ATEX zone) | Impact on thermal dissipation and cabinet size |
Derating by altitude and temperature
Mexico has altitudes that significantly impact the current capacity of a drive. Applying the correct factors from the design avoids overtemperature and premature breakdowns.
Derating by altitude
Above 1 000 m a.s.l., apply −1% of rated current for every additional 100 m.
| Altitude (m a.s.l.) | Factor | Reference city |
|---|---|---|
| 0–1 000 | 1.00 (no derating) | Veracruz, Tampico |
| 1 500 | 0.95 | Guadalajara |
| 2 240 | 0.88 | Mexico City |
| 2 500 | 0.85 | Toluca |
| 3 000 | 0.80 | Puebla alta / mines |
| 4 000 | 0.70 | High altitude mines |
Derating by temperature
Base 40°C. Above, apply −1.5% of rated current for each additional degree.
| Ambient temperature (°C) | Factor | Context |
|---|---|---|
| ≤ 40 | 1.00 (nominal) | Electrical heated room |
| 45 | 0.925 | Technical room without A/C |
| 50 | 0.85 | Outdoor with direct sun |
| 55 | 0.775 | Non-ventilated cabinet |
| 60 | 0.70 | Hot process, oven |
Apply both factors multiplicatively when altitude and temperature exceed their limits simultaneously.
Integrated Protections (ANSI Designation)
Modern drives incorporate electronic protections that complement or replace external protection relays, reducing costs and response times.
Overtemperature (thermal)
I²t thermal model of the motor and NTC/PTC sensor in the IGBT. Trip with adjustable pre-alarm.
Outflow overcurrent
Instantaneous and delayed electronic limitation to protect motor windings and IGBTs.
Phase imbalance
Detects output current asymmetry greater than the configured threshold; protects against winding failure.
Network underlay
Trip with hysteresis when Vred falls below the threshold. Automatic reset configurable after replacement.
Overvoltage of DC network / bus
DC bus monitoring; Activates braking resistor or regenerative mode before overvoltage trip.
Incomplete start / rotor lock
Detects blocked motor or excessive load during starting; maximum force ramp with time limit.
Supported communication protocols
Integration with PLC, DCS and SCADA is critical for process automation. We select drives with the native protocol of the existing control system.
Modbus RTU/TCP
Universal RS-485 or Ethernet standard. Compatible with all PLCs on the market. Up to 247 RTU nodes.
Profibus DP
Siemens protocol with wide penetration in the process industry. Up to 12 Mbps, cycle det. <1ms.
PROFINET
Siemens Industrial Ethernet. Real time IRT (<1 ms), ideal for motion axes and CNC machines.
EtherNet/IP
Allen-Bradley/Rockwell protocol. TCP/IP + CIP. Compatible with FactoryTalk and Studio 5000.
DeviceNet
CAN network for compact Rockwell PLCs. Trunk/branch topology, up to 64 nodes.
BACnet/LON
For HVAC systems and building management. Integration with BMS and energy monitoring systems.
CANopen/DriveProfile
Motion applications and process machinery. Axis synchronization with DSP402 profile.
OPC-UA/IIoT
Direct connectivity to IIoT platforms (Azure IoT Hub, AWS IoT, MindSphere) for process analytics.
Manufacturers we work with
We select the brand based on the process requirements, communication protocol, voltage level and project budget.
ABB
- ACS180/ACS580
- ACS880 (AFE)
- ACS6000 (MV)
SIEMENS
- SINAMICS G120 / G130
- SINAMICS S120 (servo)
- SINAMICS GM150 (MV)
Schneider
- Altivar ATV320
- Altivar Process ATV630
- Altivar 6000 (MV)
Triol
- AT24 (LV)
- AT27 (MV Oil&Gas)
- Sensorless vector control
Reference regulatory framework
The standards presented are of a information The rules applicable to each project — including national standards, requirements of the client or competent authority — are determined and agreed at the basic engineering stage in accordance with the specific requirements of the scope contracted.
EMC for drives. Defines C1–C4 categories, conducted/radiated emissions limits and immunity requirements. Mandatory for CE Marking.
Electrical and thermal safety. Insulation, protections, surface temperature and protective earth requirements.
Communication profile. Generic interface for industrial networks (PROFIdrive, CiA402). Facilitates multi-brand integration with PLCs.
Harmonics in MV/LV network >16 A. Establishes limits of THDi and individual harmonic currents at the point of common connection (PCC).
ANSI/IEEE harmonics standard. Reference in projects for North America. Sets THDv ≤5% and THDi according to short circuit ratio in the PCC.
Power Conversion Equipment. Required when the project follows NEC (NFPA 70) or the customer requires UL listing for equipment installed in the US or with NFPA code.
Common doubts about frequency converters
How much energy savings does a frequency changer generate?
What rules govern the electromagnetic compatibility of VFDs?
What is an AFE-type VFD and when should it be used?
How does altitude affect the performance of a variator?
Does VMS Energy install variable frequency drives of any brand?
Triol AT24 variants available with direct quote
If your project requires a Triol variator, you can apply for a quote directly from VMShop — without bidding, with technical validation included and response within 24 hours.
Installed and commissioned variances
More than 60 variable frequency drives inspected, rehabilitated or commissioned on offshore platforms, food industry, mining, infrastructure and oil extraction.
KU-H, AYATSIL and MALOOB-D platforms — Pemex
Active Kumaza, Campeche
Commissioning of a 900 hp Robicon Perfect Harmony drive on 4 160 V; technical and visual inspection in the field of 900 and 800 HP Siemens drives; review, evaluation and correction of VDF-08-02; and inspection, component replacement and field testing of the VDF-10-01.
Baker Hughes
Campeche (offshore)
Service, supply, installation and commissioning of fourteen E-Cabinet frequency changers for intemperie.
AMOCA and MIZTON — Pemex
Tabasco
Service, supply, installation and commissioning of eight E-Cabinet frequency changers for intemperie in AMOCA and six in MIZTON.
SLB
Tabasco and the Caribbean
Engineering, supply, installation and commissioning of two Triol brand 1,000 HP medium voltage drives in a NEMA 4X cabinet, and a 75 HP self-supporting drive for oil extraction on land.
Pemex
Tabasco (Outward)
Performance evaluation service to six variable frequency drives in application of electro-centrifugal pumping on marine platform.
Cotemar
City of Carmen and Veracruz
Supply of six 50, 75 and 200 HP ABB frequency changers for marine platform; installation, interconnection and configuration of three others; and engineering, supply and commissioning of a 300 HP ranger for ground-based oil extraction.
Soft Drinks Bottling Company, Colima
Colima
Engineering, supply, installation and commissioning of a 200 HP Triol brand variable speed drive.
Tamazula Sugar Mill
Jalisco
Engineering, supply, installation and commissioning of a 300 HP regenerative drive from Schneider Electric; and technical training on ABB ACS880/ACQ580 drives and Rockwell RSLogix 5000/500 controllers.
Mining operation
Durango
Supply and commissioning of a Schneider Electric Altivar 980 700 HP variator to move a 900 m water column.
Infrastructure project
State of Mexico
Integration and commissioning of twelve NEMA 12 cabinets with Siemens drives and Profinet control via SCADA, for ventilation and extraction jetfans within a tunnel.
Reduce your power consumption with the correct variator!
Share with us the engine data, load profile and site altitude. Our engineers calculate derating, topology and ROI. We will contact you in less than 24 business hours; The study time depends on the scope.