Industrial Transformers
From selection to commissioning

Multi-brand supply, installation, acceptance testing and commissioning of distribution and power transformers for the industry in Mexico.

Up to 100 MVA LV / MV / HV up to 400 kV Dry and in oil National and international regulations FAT and SAT tests included
Supply Portfolio

Types of transformers we supply and install

Selection based on process requirements: voltage level, environment, power, vector group and efficiency class.

Distribution < 2 500 kVA

Primary 6–34.5 kV → secondary 220–480 V. Groups Dyn11 or Yyn0. Industrial, commercial use and end customer substations.

Dry IP20–IP54ONAN OilNOM-003-ENER

Power > 2 500 kVA

Up to 100 MVA. Refrigeration ONAN, ONAF, OFAF, ODAF. For generating plants, transmission substations and large industries.

HV/EATODAFBIL up to 1550 kV

Dry transformer — epoxy resin

Class F or H. For indoors, fire risk areas, hospitals, airports, platforms and high altitude areas (> 3 000 m).

F/H ClassIP20–IP54No liquid maintenance

Transformer in mineral oil

ASTM D27 mineral oil or vegetable oil (BIOTEMP). Natural cooling (ONAN), blowers (ONAF) or pumps (OFAF/ODAF). Greater power range.

ONAN / ONAFOFAF / ODAFContainment bucket

Autotransformer

Voltage reduction or increase with common winding. Application in star-delta starting, network voltage adjustment and coupling of systems with different nominal voltages.

Y-Δ Startvoltage adjustment

Special transformers

6/12 pulse rectifiers (harmonic reduction), electric arc furnaces, grounding (NGR/NER), measurement (TC/TP) and grounding impedance.

12p rectifierEAF OvenNGR
Selection engineering

Key Specification Parameters

Incorrect selection of the vector group or the BIL level are the most frequent causes of premature failure in industrial transformers.

ParameterTypical value/rangeSelection criteria
Apparent power (kVA)15 – 100,000 kVADemand factor + diversity factor; reserve 15–25% margin
Primary/secondary stress220 V – 400 kVAccording to CFE network or generator; tolerance ±5%
Vector groupDyn11, YNd11, Dd0, Yyn0Dyn11 standard distribution; YNd11 for generators; Dd0 for inter-bus
BIL level (kV peak)20 – 1550 kVZone of highest storm activity: bil elevated + lightning rod ZnO enubels
Short circuit impedance (Uk%)4 – 12%Low Uk = Major start currents; High Uk = Best voltage regulation
Cooling classONAN / ONAF / OFAF / Seco F-HUnventilated interior → dry; exterior with space → ONAN oil
Tap connections±2x2.5% or ±5% OCTC/OLOLTC if network variation > ±5%; OCTC yes stable network
Efficiency classNER1 / NER2 (NOM-003-ENER)NER2 mandatory in CFE projects; NER1 in private supply
IEC 60076 — Acceptance tests

FAT and SAT: factory and site tests

VMS Energy documentally analyzes the factory acceptance tests (FAT) and performs the site tests (SAT) before the final energized.

IEC 60076-1 §11.1

Transformation ratio

Measurement of the transformation ratio at each tap. Tolerance: ±0.5% with respect to the nominal value.

IEC 60076-1 §11.2

Winding resistance

Measurement at known temperature in each winding. Allows you to calculate load losses and verify connection integrity.

IEC 60076-1 §11.4

Impedance and load losses

Short circuit test: determines Uk% and PCC. Tolerance: ±5% in losses, ±7.5% in Uk% for < 630 kVA.

IEC 60076-1 §11.5

No-load losses and no-load current

Test at nominal voltage and frequency. Determine P0 and I0%. Key to projecting energy costs in continuous operation.

IEC 60076-3

Dielectric test – applied voltage

Application of AC voltage for 60 s between windings and ground. Verifies integrity of the insulation system.

IEC 60076-5

Short circuit resistance

Dynamic short circuit test with asymmetric peak current. Verify that the transformer withstands electromagnetic forces during a fault.

Commercial alliance and multi-brand portfolio

Manufacturers we supply

VMS Energy evaluates the best option according to application, budget, delivery time and local technical support. Access to national inventory for rapid response.

We also supply

WEG

Dry and oil transformers for industrial and energy generation applications

DryIn oil

ABB

TrafoStar / RESIBLOC dry / OFAF up to 1000 MVA

DryIn oilHigh power

SIEMENS

GEAFOL (dry) / DTTH / EMDS up to 400 kV

DryHigh voltage

Schneider Electric

Trihal (dry) / Minera / Unibloc distribution

DryDistribution
Regulatory framework

Reference regulatory framework

The standards presented are of a information The applicable legislation — including national standards, requirements of the client or competent authority — is determined and agreed at the basic engineering stage in accordance with the specific requirements of the project.

IEC 60076-1Power transformers. General requirements: tolerances, connections, data plates.
IEC 60076-3Insulation levels, dielectric tests and air separations.
IEC 60076-5Ability to withstand short circuit. Dynamic and thermal forces during failure.
IEC 60076-11Dry type transformers. Temperature classes and thermal aging tests.
NOM-003-ENEREnergy efficiency for distribution transformers. NER1 and NER2 classes in Mexico.
CFE L0000-06CFE specification for distribution transformers in public system substations.
Frequently asked questions

Most common technical doubts

What rules govern industrial transformers?
The series IEC 60076 is the main international standard: IEC 60076-1 (general requirements), 60076-2 (temperature), 60076-3 (dielectric insulation and testing), 60076-5 (short circuit resistance) and IEC 600 76-11 for dry transformers. In Mexico it is complemented by NOM-003-ENER (efficiency) and CFE L0000-06 for CFE projects.
What does the vector group Dyn11 mean?
D = primary winding in delta (Delta), and = devanado secundario en estrella (wye), N = accessible neutral on the secondary, 11 = 330° phase shift (equivalent to −30°) between phase voltages. The Dyn11 is the standard group for MV/LV distribution transformers because the accessible neutral allows for single-phase distribution and system grounding.
What is the difference between dry transformer and oil?
The dry transformer uses epoxy resin as insulation: suitable for indoors, fire-risk zones and high-level bathrooms; does not require containment. oil transformer uses dielectric mineral oil: higher cooling efficiency, higher power range (up to 100 MVA+) and lower cost per kVA, but requires {Quintto and more space. For > 4000 m we recommend dry with derating or consult the manufacturer.
What acceptance tests are performed according to IEC 60076-1?
The mandatory routine tests are: (1) transformation ratio, (2) winding resistance, (3) short-circuit impedance and load losses, (4) no-load losses and no-load current, (5) applied voltage dielectric test. Optional type tests: BIL impulse, temperature and noise test. VMS Energy accompanies the client in the factory FAT and executes the site SAT tests.
What is bil and how is it selected?
The BIL (Basic Impulse Insulation Level) is the maximum impulse voltage that supports the transformer expressed in kV crest. It is selected according to the nominal voltage of the system and the stormy area of activity: the higher the keraunic level (storm days per year), the greater the bil and the more important the coordination with ZnO lightning rod. For 34.5 kV the standard bil is 200 kV; for 115 kV is 550 kV.
Reference projects

Transformers supplied and commissioned

Nohoch-A2 Platform — Campeche Maritime Services / Pemex

Zonda de Campeche

Commissioning of a 1,500 kVA power transformer, with insulation resistance testing (Megger), ohmic winding resistance, power factor and transformation ratio (TTR).

BALAM-TA and TB platforms — Campeche Maritime Services / Pemex

Zonda de Campeche

Manufacture, supply, pre-operational electrical testing, commissioning and performance testing of two 3 500 kVA transformers at 34.5 kV and their two grounding resistors, together with a 600 A five-breaker disconnector at 34.5 kV with SEL 751 relays.

Litoral-A Platform — Pemex

Campeche (offshore)

Supply, installation and testing of a transformer in epoxy resin 1 500 kVA in 4 160/480 V with its grounding resistance, powered by a main metal clad Siemens switch 800 A in 4 160 V.

Maloob-D, ZAAP-B and ZAAP-E platforms — Pemex

Campeche (offshore)

Installation, electrical testing and commissioning of 1,500 and 1,000 kVA transformers in substations made up of Metal Clad distribution panels.

EK-A Platform — Pemex / Cotemar

Campeche (offshore)

Supply and testing of a transformer of 7.5 MVA; installation, interconnection, commissioning and performance tests of the same equipment and another of 1 500 kVA three-phase; subsequent diagnosis of the transformer of 7 500 kVA and supply of a new one for service to the intemperie.

BALAM-A Platform — Pemex

Campeche (offshore)

Primary electrical testing of six oil- and air-cooled step-up and phase-shift transformers and 34.5 kV main distribution transformers; rehabilitation of fourteen transformers on the platform.

BALAM-TB Platform — Cotemar

Campeche (offshore)

Review, evaluation and diagnosis of a 1,500 kVA transformer; rehabilitation of a 500 kVA phase shift transformer and a 500 kVA booster; and interconnection, commissioning and performance testing of a 1,500 kVA power transformer.

PG-ZAAP-C, MALOOB and AYATSIL-B platforms — Pemex

Campeche (offshore)

Rehabilitation of distribution and power transformers dry type: 20 MVA TR-01, 10 MVA TR-15, 5 MVA TR-20, 7.5 MVA TR-PP-BR, TTR-18 and TR-S-MBB; and opinion and diagnosis of TR-01 to TR-04 of 20 MVA.

AKAL-B4, B5, C6, C7 and BALAM-TE platforms — Pemex

Campeche (offshore)

Rehabilitation and repair of transformers oil type: TR-2000 2,000 kVA, TX-4900A 2,240 kVA, TX-4900B 1,000 kVA, TX-4910A and TX-4910C 2,000 kVA; and connection, electrical tests, oil change and repair of leaks in the radiators of the TRD-56 and TRE-76.

Pemex

Campeche

Supply of a three-phase power transformer with a capacity of 15,000 kVA, with a capacity for three phases and 60 Hz, immersed in biodegradable dielectric oil liquid.

Request your transformer specification

Share your process data and our team prepares a technical proposal with multi-brand selection and cost-lifecycle analysis.

Transformers in operation needing diagnostics?

The physical-chemical and DGA analysis of dielectric oil is the first line of predictive maintenance for oil-filled transformers. VMS Energy offers the complete diagnosis.

See FQ and DGA analysis of oil →