Condition monitoring for rotating equipment
Vibration · SCADA · Predictive maintenance
Detect the fault before it becomes a shutdown. We integrate vibration, temperature, current and process sensors into your PLC and SCADA, we configure alarms by severity and carry out the maintenance that the diagnosis indicates, with the support of specialized technological allies.
Failure rarely begins with unemployment
First the condition of the equipment changes: the vibration increases, a bearing heats up, the current becomes unbalanced. Monitoring detects that signal and maintenance takes action before major damage occurs. The value is in seeing the failure in time to plan the intervention, not in reacting to the strike.
Architecture of a condition monitoring system
We design, supply and integrate each layer. If your plant already has PLC, SCADA or DCS, we take advantage of it: monitoring adds to the existing infrastructure instead of creating an island of data.
Critical equipment
Motors, pumps, fans, compressors, reducers and turbines selected by criticality, not by inertia.
Sensors
Accelerometers, RTDs, current transformers, tachometers and process variables, wired or wireless.
Acquisition
PLC, gateway or edge equipment that digitizes, filters and sends information with industrial protocols.
SCADA / Historian
Operational and historical context: vibration is interpreted together with load, speed and process.
Analysis
Trends, FFT spectrum and severity alarms, with base line specific to each team.
Predictive maintenance
Work order with probable cause and priority. It intervenes before the stoppage and is verified afterwards.
Variables that reveal the real condition of the equipment
No variable tells the whole story. The correct combination depends on the type of equipment and its most likely failure modes.
ISO 20816 / ISO 13373
Vibration
RMS speed for global severity; acceleration and envelope for bearings and gears. Detecta desEygo, misalignment, mechanical slack, bearing wear and resonance.
Pt100 RTD/thermocouple
Temperature
Bearings, pillow blocks, windings and casing. A sustained increase confirms what the vibration anticipates: poor lubrication, overload or cooling problems.
Measurement in MCC / drive
Current and electrical variables
Consumption, imbalance between phases and load trend. Reveals engine and driven equipment problems that are not always seen in vibration.
Tacometer / phase reference
Speed (RPM)
Essential in equipment with a drive: it allows you to compare readings at different speeds and identify which frequencies of the spectrum correspond to each fault.
Pressure · flow · level
Process
The operating context that avoids false alarms: a pump outside its operating point vibrates differently than one with damaged bearings.
API 670 (critical machinery)
Machinery protection
In critical turbines and compressors, monitoring also protects: shaft displacement, axial position and automatic tripping against dangerous vibration.
What we detect in each type of equipment
| Team | Failure modes that monitoring anticipates | Key variables |
|---|---|---|
| Electric motors | Rolling-out, desalination, misalignment, rotor problems, overheating of devanates | Vibration, temperature, current |
| Bombs | Cavitation, misalignment, bearing and seal wear, off-design point operation | Vibration, pressure, flow |
| Fans | Imbalance due to material accumulation, structural looseness, resonance | Vibration, speed |
| Reducers | Wear of gears, bearings, poor lubrication | Vibration (alarm), temperature |
| Compressors | Bearings, misalignment, valve problems, operating instability | Vibration, temperature, process |
| Turbines and generators | Shaft displacement, bearing wear, thermal imbalance | Proximity, vibration, temperature |
Reference vibration levels (ISO 20816-3)
RMS speed in mm/s, measured in the housing of industrial machines greater than 15 kW. They are the starting point: the end alarm thresholds are adjusted with the baseline of each equipment and the manufacturer's recommendation.
| Machine class | Base | Zone A · new | Zone B · acceptable | Zone C · alert | Zone D · risk of damage |
|---|---|---|---|---|---|
| Group 2 · 15–300 kW | Rigid | ≤ 1.4 | 1.4–2.8 | 2.8–4.5 | > 4.5 |
| Group 2 · 15–300 kW | Flexible | ≤ 2.3 | 2.3–4.5 | 4.5–7.1 | > 7.1 |
| Group 1 · 300 kW–50 MW | Rigid | ≤ 2.3 | 2.3–4.5 | 4.5–7.1 | > 7.1 |
| Group 1 · 300 kW–50 MW | Flexible | ≤ 3.5 | 3.5–7.1 | 7.1–11.0 | > 11.0 |
More important than the absolute value is the trend: a device that goes from 1.5 to 2.5 mm/s in a few weeks deserves attention even if it is still in zone B.
Start where your plant is today
Not all equipment needs online monitoring. Criticality, redundancy, cost of downtime and access to equipment define the correct technique for each.
Starting point
Criticality diagnosis
Inventory of rotating assets, failure history and criticality matrix. Result: which equipment to monitor, with what variables and with what frequency, and a scope estimate.
Medium criticality equipment
Route monitoring
Periodic readings with portable equipment, with trends and condition report per equipment. Executed with specialist allies and coordinated by VMS.
Critical or difficult to access equipment
Online monitoring
Permanent sensors, gateway and link to the plant SCADA or DCS, with severity alarms. Ideal for teams without redundancy, remote or offshore.
Closing of the cycle
O&M and response
Maintenance of motors and rotating equipment, replacement of bearings, alignment, adjustment of protections and post-intervention verification.
One responsible, with specialists where they are needed
VMS integrates and responds to the entire system. For specialized analysis and monitoring platforms we work with technological allies, without binding us to a single brand.
| Activity | Who executes it |
|---|---|
| Monitoring architecture engineering | VMS Energy |
| Supply of sensors, #Turns and boards (multimark) | VMS Energy |
| Installation, wiring and commissioning | VMS Energy |
| Integration to PLC, SCADA or DCS and alarm configuration | VMS Energy |
| Advanced spectral analysis and specialized diagnosis | Specialist allies, coordinated by VMS |
| Monitoring software platform | Allied manufacturer, implemented by VMS |
| Predictive and corrective maintenance of rotating equipment | VMS Energy |
Projects in vibrations, control and rotating equipment
Dragon Group — geothermal plant
Nayarit
Generation control system with CFE synchronization and vibration system with PLC S7, HMI and machinery protection monitoring Bently Nevada 3500.
Pemex — KU-H Platform
Campeche (offshore)
Configuration and commissioning of the PLC-based control system for the TAB1290A and TAB1290B screw type pumps.
Cotemar — Abkatún-A Platform
Campeche (offshore)
Integration of signals to the platform monitoring and control system.
Cotemar — Hercules Ship
Veracruz
Major maintenance on 1,050 kW, 690 V Bow Thruster motor: review of windings, bearings and mechanical alignment.
LINDE — Cantarell Nitrogen Plant
Cantarell Operations
Maintenance of a 2,560 HP squirrel cage engine and a 600 HP engine in the nitrogen generation plant.
Road infrastructure
State of Mexico
Integration and commissioning of 12 cabinets with drives and Profinet control via SCADA for the extraction fans of a tunnel.
Where an unscheduled stoppage costs more
Pumping, compression and generation on platforms and vessels, where each visit costs logistics and remote monitoring reduces personnel exposure.
Drain pumping, ventilation, grinding and transportation: equipment in aggressive environments and continuous operation.
Refrigeration compressors, process pumps and fans where a stoppage compromises product and cold chain.
Questions about condition monitoring
How is condition monitoring different from preventive maintenance?
The preventive intervenes by calendar or hours of operation, whether or not the equipment is damaged. Condition monitoring measures the actual condition of the equipment and schedules intervention when data warrants it. Reduces both unexpected downtime and unnecessary maintenance.
Do I need online monitoring or are regular routes enough?
Depends on criticality. Equipment without backup, with costly downtime or difficult to access (offshore, remote) justify online monitoring. Equipment with redundancy or less impact is usually well covered with monthly or quarterly routes. The criticality diagnosis defines the appropriate mixture.
Can you integrate into the SCADA or DCS I already have?
Yes. Current sensors and #Turns communicate through industrial protocols such as Modbus TCP/RTU, Profinet, EtherNet/IP or OPC UA. We integrate signals and alarms into your existing system so that operation sees the condition of the equipment along with the process.
What failures does vibration analysis detect?
Imbalance, misalignment, mechanical looseness, wear of bearings and gears, cavitation in pumps and structural resonances, among others. Combined with temperature and current, it also helps distinguish electrical problems with the motor from mechanical problems with the driven equipment.
What standard defines acceptable vibration levels?
The reference for industrial machines is the ISO 20816 series (formerly ISO 10816), which classifies severity into zones A, B, C and D according to machine size and type of base. For critical process machinery, API 670 defines protection systems. Thresholds are adjusted with each team's baseline.
Does it work on frequency-variator equipment?
Yes, provided that speed is recorded along with vibration, this compares readings at different speeds and correctly identifies the frequencies of failure in the spectrum.
Where should we start?
For a criticality diagnosis and a driver in the teams that cost the most when they stop. With measurable results in those teams, it is decided whether to expand the scope.
What equipment from your plant can't fail?
Let's start with a criticality diagnosis: we identify the equipment that costs the most when it stops and we define what to monitor, how and how often.
Do you also need electrical predictive?
Infrared thermography, VLF tests on medium voltage cables and transformer diagnostics complement the monitoring of rotating equipment.
See electrical predictive maintenance → · See Industry 4.0 / IIoT →