VMS Energy · Operation and Maintenance · Condition Monitoring

Condition monitoring for rotating equipment

Vibration · SCADA · Predictive maintenance

Detect the fault before it becomes a shutdown. We integrate vibration, temperature, current and process sensors into your PLC and SCADA, we configure alarms by severity and carry out the maintenance that the diagnosis indicates, with the support of specialized technological allies.

Engines · Pumps · Compressors · Turbines ISO 20816 Criterion PLC · SCADA · DCS integration Offshore experience
5
variables per asset
ISO 20816
severity criterion
Modbus · Profinet
integration into control
Offshore
Gulf of Mexico
Multi-brand
sensors and platforms
Why monitor

Failure rarely begins with unemployment

First the condition of the equipment changes: the vibration increases, a bearing heats up, the current becomes unbalanced. Monitoring detects that signal and maintenance takes action before major damage occurs. The value is in seeing the failure in time to plan the intervention, not in reacting to the strike.

Evolution of a failure in rotating equipment Condition curve descending with time: normal operation, early anomaly detectable by monitoring, degradation, alarm and functional failure. Planned intervention occurs between detection and failure. Operating time Equipment condition Window to intervene in a planned way Normal operation Early anomaly (monitoring detects it) Degradation Alarm Failure/stop
Between the first signal and the failure there is an interval. Condition monitoring exists to take advantage of it: schedule the shutdown, have the spare part and avoid cascading damage.
From data to decision

Architecture of a condition monitoring system

We design, supply and integrate each layer. If your plant already has PLC, SCADA or DCS, we take advantage of it: monitoring adds to the existing infrastructure instead of creating an island of data.

Critical equipment

Motors, pumps, fans, compressors, reducers and turbines selected by criticality, not by inertia.

Sensors

Accelerometers, RTDs, current transformers, tachometers and process variables, wired or wireless.

Acquisition

PLC, gateway or edge equipment that digitizes, filters and sends information with industrial protocols.

SCADA / Historian

Operational and historical context: vibration is interpreted together with load, speed and process.

Analysis

Trends, FFT spectrum and severity alarms, with base line specific to each team.

Predictive maintenance

Work order with probable cause and priority. It intervenes before the stoppage and is verified afterwards.

What we monitor

Variables that reveal the real condition of the equipment

No variable tells the whole story. The correct combination depends on the type of equipment and its most likely failure modes.

ISO 20816 / ISO 13373

Vibration

RMS speed for global severity; acceleration and envelope for bearings and gears. Detecta desEygo, misalignment, mechanical slack, bearing wear and resonance.

Pt100 RTD/thermocouple

Temperature

Bearings, pillow blocks, windings and casing. A sustained increase confirms what the vibration anticipates: poor lubrication, overload or cooling problems.

Measurement in MCC / drive

Current and electrical variables

Consumption, imbalance between phases and load trend. Reveals engine and driven equipment problems that are not always seen in vibration.

Tacometer / phase reference

Speed (RPM)

Essential in equipment with a drive: it allows you to compare readings at different speeds and identify which frequencies of the spectrum correspond to each fault.

Pressure · flow · level

Process

The operating context that avoids false alarms: a pump outside its operating point vibrates differently than one with damaged bearings.

API 670 (critical machinery)

Machinery protection

In critical turbines and compressors, monitoring also protects: shaft displacement, axial position and automatic tripping against dangerous vibration.

Applications on critical assets

What we detect in each type of equipment

TeamFailure modes that monitoring anticipatesKey variables
Electric motorsRolling-out, desalination, misalignment, rotor problems, overheating of devanatesVibration, temperature, current
BombsCavitation, misalignment, bearing and seal wear, off-design point operationVibration, pressure, flow
FansImbalance due to material accumulation, structural looseness, resonanceVibration, speed
ReducersWear of gears, bearings, poor lubricationVibration (alarm), temperature
CompressorsBearings, misalignment, valve problems, operating instabilityVibration, temperature, process
Turbines and generatorsShaft displacement, bearing wear, thermal imbalanceProximity, vibration, temperature
Severity criteria

Reference vibration levels (ISO 20816-3)

RMS speed in mm/s, measured in the housing of industrial machines greater than 15 kW. They are the starting point: the end alarm thresholds are adjusted with the baseline of each equipment and the manufacturer's recommendation.

Machine classBaseZone A · newZone B · acceptableZone C · alertZone D · risk of damage
Group 2 · 15–300 kWRigid≤ 1.41.4–2.82.8–4.5> 4.5
Group 2 · 15–300 kWFlexible≤ 2.32.3–4.54.5–7.1> 7.1
Group 1 · 300 kW–50 MWRigid≤ 2.32.3–4.54.5–7.1> 7.1
Group 1 · 300 kW–50 MWFlexible≤ 3.53.5–7.17.1–11.0> 11.0

More important than the absolute value is the trend: a device that goes from 1.5 to 2.5 mm/s in a few weeks deserves attention even if it is still in zone B.

Service modalities

Start where your plant is today

Not all equipment needs online monitoring. Criticality, redundancy, cost of downtime and access to equipment define the correct technique for each.

Starting point

Criticality diagnosis

Inventory of rotating assets, failure history and criticality matrix. Result: which equipment to monitor, with what variables and with what frequency, and a scope estimate.

Medium criticality equipment

Route monitoring

Periodic readings with portable equipment, with trends and condition report per equipment. Executed with specialist allies and coordinated by VMS.

Critical or difficult to access equipment

Online monitoring

Permanent sensors, gateway and link to the plant SCADA or DCS, with severity alarms. Ideal for teams without redundancy, remote or offshore.

Closing of the cycle

O&M and response

Maintenance of motors and rotating equipment, replacement of bearings, alignment, adjustment of protections and post-intervention verification.

Scope

One responsible, with specialists where they are needed

VMS integrates and responds to the entire system. For specialized analysis and monitoring platforms we work with technological allies, without binding us to a single brand.

ActivityWho executes it
Monitoring architecture engineeringVMS Energy
Supply of sensors, #Turns and boards (multimark)VMS Energy
Installation, wiring and commissioningVMS Energy
Integration to PLC, SCADA or DCS and alarm configurationVMS Energy
Advanced spectral analysis and specialized diagnosisSpecialist allies, coordinated by VMS
Monitoring software platformAllied manufacturer, implemented by VMS
Predictive and corrective maintenance of rotating equipmentVMS Energy
Experience

Projects in vibrations, control and rotating equipment

Dragon Group — geothermal plant

Nayarit

Generation control system with CFE synchronization and vibration system with PLC S7, HMI and machinery protection monitoring Bently Nevada 3500.

Pemex — KU-H Platform

Campeche (offshore)

Configuration and commissioning of the PLC-based control system for the TAB1290A and TAB1290B screw type pumps.

Cotemar — Abkatún-A Platform

Campeche (offshore)

Integration of signals to the platform monitoring and control system.

Cotemar — Hercules Ship

Veracruz

Major maintenance on 1,050 kW, 690 V Bow Thruster motor: review of windings, bearings and mechanical alignment.

LINDE — Cantarell Nitrogen Plant

Cantarell Operations

Maintenance of a 2,560 HP squirrel cage engine and a 600 HP engine in the nitrogen generation plant.

Road infrastructure

State of Mexico

Integration and commissioning of 12 cabinets with drives and Profinet control via SCADA for the extraction fans of a tunnel.

Sectors

Where an unscheduled stoppage costs more

Oil & Gas

Pumping, compression and generation on platforms and vessels, where each visit costs logistics and remote monitoring reduces personnel exposure.

Mining

Drain pumping, ventilation, grinding and transportation: equipment in aggressive environments and continuous operation.

Food & Drinks

Refrigeration compressors, process pumps and fans where a stoppage compromises product and cold chain.

Frequently asked questions

Questions about condition monitoring

How is condition monitoring different from preventive maintenance?

The preventive intervenes by calendar or hours of operation, whether or not the equipment is damaged. Condition monitoring measures the actual condition of the equipment and schedules intervention when data warrants it. Reduces both unexpected downtime and unnecessary maintenance.

Do I need online monitoring or are regular routes enough?

Depends on criticality. Equipment without backup, with costly downtime or difficult to access (offshore, remote) justify online monitoring. Equipment with redundancy or less impact is usually well covered with monthly or quarterly routes. The criticality diagnosis defines the appropriate mixture.

Can you integrate into the SCADA or DCS I already have?

Yes. Current sensors and #Turns communicate through industrial protocols such as Modbus TCP/RTU, Profinet, EtherNet/IP or OPC UA. We integrate signals and alarms into your existing system so that operation sees the condition of the equipment along with the process.

What failures does vibration analysis detect?

Imbalance, misalignment, mechanical looseness, wear of bearings and gears, cavitation in pumps and structural resonances, among others. Combined with temperature and current, it also helps distinguish electrical problems with the motor from mechanical problems with the driven equipment.

What standard defines acceptable vibration levels?

The reference for industrial machines is the ISO 20816 series (formerly ISO 10816), which classifies severity into zones A, B, C and D according to machine size and type of base. For critical process machinery, API 670 defines protection systems. Thresholds are adjusted with each team's baseline.

Does it work on frequency-variator equipment?

Yes, provided that speed is recorded along with vibration, this compares readings at different speeds and correctly identifies the frequencies of failure in the spectrum.

Where should we start?

For a criticality diagnosis and a driver in the teams that cost the most when they stop. With measurable results in those teams, it is decided whether to expand the scope.

What equipment from your plant can't fail?

Let's start with a criticality diagnosis: we identify the equipment that costs the most when it stops and we define what to monitor, how and how often.

Do you also need electrical predictive?

Infrared thermography, VLF tests on medium voltage cables and transformer diagnostics complement the monitoring of rotating equipment.

See electrical predictive maintenance →  ·  See Industry 4.0 / IIoT →